Constant 700s All in One Scopemeter
Features Constant 700S All In One ScopeMeter:
Auto setting digital storage scope 5 MHz
Frequency counter up to 1.3 GHz
Function generator up to 5Mhz
Logic analyzer
Display 160 by 160 pixel graphic LCD (63mm x 63 mm)
Measurement rate: 4 times/second for digital, 7 times/second for bar-graph
Direct print capability through recommended thermal printer
Auto power-off after 30 minutes, set up mode (enable/disable)
RS 232 computer interface: 1200, 2400, 4800, 9600 bps baud rates, 8 bit data, 1 stop bit, none parity bit
Store up to 15 screens either text or graph
HELP key
Automatic Testing System & Memory
4 directions cursor
Set up for printer, parity, beeper, back light, baud rate, dBm reference, sleep mode
User manual in SET UP
Frequency counter displays hold mode and rpm
Display ”OVER” with beeper sound for over range indication
Specification Constant 700s:
DMM
|
AC Current
(True RMS) (auto/manual)
|
Range
|
Resolution
|
Accuracy
|
Overload
Protection
|
50Hz ~ 1kHz
|
1kHz ~ 10kHz
|
40mA
|
10µA
|
±(1.2% rdg + 10
dgts)
|
±(4.0% rdg + 10
dgts)
|
250V/500mA
fused
|
400mA
|
100µA
|
4A
|
1mA
|
±(2.0% rdg + 10
dgts)
|
±(4.0% rdg + 10
dgts)
|
250V/20A fused
|
20A
|
10mA
|
AC Voltage
(True RMS)
|
Range
|
Resolution
|
Accuracy
|
50Hz ~ 1kHz
|
1kHz ~ 10kHz
|
10kHz ~ 30 KHz
|
400mV
|
0.1mV
|
±(1.0% rdg + 10
dgts)
|
±(5.0% rdg + 10
dgts)
|
ns
|
4V
|
1mV
|
±(0.75% rdg +
10 dgts)
|
±(2.0% rdg + 10
dgts)
|
±(5.0% rdg + 10
dgts)
|
40V
|
10mV
|
±(0.75% rdg +
10 dgts)
|
±(1.0% rdg + 10
dgts)
|
±(5.0% rdg + 10
dgts)
|
400V
|
100mV
|
±(0.75% rdg +
10 dgts)
|
±(1.0% rdg + 10
dgts)
|
±(5.0% rdg + 10
dgts)
|
700V
|
1V
|
±(1.0% rdg + 10
dgts)
|
ns
|
ns
|
DC Current
(auto / manual)
|
Range
|
Resolution
|
Accuracy
|
Overload
Protection
|
40mA
|
10µA
|
±(1.2% rdg + 10
dgts)
|
250V/500mA
fused
|
400mA
|
100µA
|
4A
|
1mA
|
±(1.5% rdg + 10
dgts)
|
250V/20A fused
|
20A
|
10mA
|
DC Voltage
(auto / manual)
|
Range
|
Resolution
|
Accuracy
|
Input Impedance
|
Overload
Protection
|
400mV
|
0.1mV
|
±(0.3% + 5
digits)
|
10MΩ
|
1000V DC or AC
peak with 10 seconds
|
4V
|
1mV
|
40V
|
10mV
|
400V
|
100mV
|
1000V
|
1V
|
Resistance
|
Range
|
Resolution
|
Accuracy
|
Overload
Protection
|
400Ω
|
0.1Ω
|
±(0.5% + 10
digits)
|
250V DC or AC peak within 10 seconds
|
4kΩ
|
1Ω
|
40kΩ
|
10Ω
|
400kΩ
|
100Ω
|
4MΩ
|
1kΩ
|
40MΩ
|
10kΩ
|
±(1.0% + 5
digits)
|
|
Capacitance
|
|
Range
|
Resolution
|
Accuracy
|
40n/400n/
4µ/40µ/
100µF
|
0.01n/0.1n/
1n/10n/
100nF
|
±(2.0% + 10
digits)
|
Diode Test
|
Resolution 1mV,
Accuracy ±(2.0% rdg ± 5 dgts), Max 5V Open Circuit
|
Continuity
|
If continuity
exists ≤ 60Ω, built in buzzer will sound
|
Display
|
3¾ digits, 3999 counts
|
Digital Storage
Oscilloscope
|
Rising Time
|
Less than 15nS
|
Input Impedance
|
1MΩ
|
Vertical
|
Number of
Channel
|
1 channel
|
Sensitivity
|
10mV/div -
200V/div (14 divisions)
|
Bandwidth
|
DC to 5MHz
|
Sample Rate
|
25 x 106
samples/s
|
Input
Protection
|
600Vpp
|
Horizontal
|
Sweep : 125ns ~
2s/div (23 divisions), Mode : Auto
|
Trigger
|
Auto / Manual
with slope
|
rising, falling
|
Trigger
Adjustable
|
15% ~ 85%
|
Input Impedance
|
CH A 1MΩ; CH B
50MΩ
|
Maximum Input
Voltage
|
CH A 100Vpp; CH
B 5Vpp
|
Simultaneously display frequency, period, and rpm
|
Frequency
Counter
|
Range
|
5Hz ~ 1.3GHz
|
Display
|
8 digits
|
Period
Measurement
|
5Hz ~ 100MHz
|
Internal Gate
Time
|
0.1s, 1s, 10s
|
Input
Measurement
|
CH A : 5Hz ~
40MHz ; CH B : 40MHz ~ 1.3GHz
|
Input
Sensitivity
|
5Hz ~ 10MHz
|
100mVrms
|
10MHz ~ 40MHz
|
200mVrms
|
40MHz ~ 80MHz
|
300mVrms
|
80MHz ~ 1.3GHz
|
200mVrms
|
Min/Max/Avg
|
Records min,
max, and average; History graph display
|
Hold
|
Captures
current reading
|
Peak Hold
|
Records peak
max, min; History graph display
|
Function
Generator
|
Output
|
Sine, triangle,
square wave
|
Range
|
40Hz ~ 50MHz (6
range)
|
Display
|
3 digits
|
Output
Impedance
|
600Ω
|
Amplitude
|
2 ~ 10Vpp
|
Duty Cycle
|
25% ~ 75%
|
Display
frequency, period, duty cycle, and amplitude simultaneous in one screen
|
Logic Analyzer
|
Vertical
|
Input Channel
|
|
1 channel
|
Input Impedance
|
|
1MΩ
|
|
Protection
Level
|
|
50Vpp Max
|
|
Horizontal
|
Sweep time : 125ns - 2s/div (23 divisions), Mode : Auto
|
General
Spesifications
|
Power
|
6 AA cells (9V
Alkaline) or 6 A (7.2V) Ni-Cd battery or 2 rechargeable Ni-Cd battery pack or
AC Adapter with internal charger
|
Size / Weight
|
H220 x W107 x
D55mm / Approx. 800g
|
Standard
Accessories
|
Alligator Clip
Set, Test Leads, Holster, AC/DC Power Adaptor with Internal Charger, Ni-Cd
Battery Pack, Scope Probe (1:1), BNC/Banana Adaptor, RS232 Interface Cable
with Software, Manual, Constant Certificate.
|
Optional
Accessories
|
AC Current Adapter, Humidity Adapter, Temperature Adapter, Thermal Printer, Deluxe Carrying Bag, Certificated of Calibration.
|
Function/Remarks |
Range |
Accuracy |
DCA / Input Sensitivity 0.25V |
50µ/5m/50m/500mA |
±2.5% rdg against full scale |
10A |
±5.0% rdg against full scale |
DCV / Input Impedance 20kΩ/V |
0.25/2.5/5/10/50V |
±2.5% rdg against full scale |
125/250/500/1000V |
ACV / Input Impedance 9kΩ/V |
10/50/125/250V |
±5.0% rdg against full scale |
500/1000V |
Resistance |
10k/100k/1M/10MΩ |
±10% rdg against full scale |
Standard Resistance Box
|
0.025/0.5/5/50/5kΩ |
±1.5% rdg against full scale |
50k/100k/200k/1MΩ |
2.5M/5MΩ |
Capacitance |
50µ/500µ/5m/50mF |
Load Current |
15m/1.5m/150µ/90µA |
Low Voltage |
0 ~ 1.5V (at x10/x100/x1k) 0 ~ 9V (at x10k) |
dB |
-10 dB ~ +22 dB |
hFE |
Read approximately hFE value of PNP/NPN transistor |
Infrared Testing |
Peak degree ±15° Distance 1 ~ 30 cm |
Diode |
Read approximately forward voltage drop of the diode |
Continuity |
If continuity exist ≤ 200Ω, built in buzzer will sound |
Battery |
9V x 1; 1.5V x 2, AA Size |
Size / Weight |
H165 x W112 x D49mm / Approx. 550g |
Standard Accessories |
Test Leads, Batteries, Manual, Carrying Case |
Function/Remarks |
Range |
Accuracy |
DCA / Input Sensitivity 0.25V |
50µ/5m/50m/500mA |
±2.5% rdg against full scale |
10A |
±5.0% rdg against full scale |
DCV / Input Impedance 20kΩ/V |
0.25/2.5/5/10/50V |
±2.5% rdg against full scale |
125/250/500/1000V |
ACV / Input Impedance 9kΩ/V |
10/50/125/250V |
±5.0% rdg against full scale |
500/1000V |
Resistance |
10k/100k/1M/10MΩ |
±10% rdg against full scale |
Standard Resistance Box
|
0.025/0.5/5/50/5kΩ |
±1.5% rdg against full scale |
50k/100k/200k/1MΩ |
2.5M/5MΩ |
Capacitance |
50µ/500µ/5m/50mF |
Load Current |
15m/1.5m/150µ/90µA |
Low Voltage |
0 ~ 1.5V (at x10/x100/x1k) 0 ~ 9V (at x10k) |
dB |
-10 dB ~ +22 dB |
hFE |
Read approximately hFE value of PNP/NPN transistor |
Infrared Testing |
Peak degree ±15° Distance 1 ~ 30 cm |
Diode |
Read approximately forward voltage drop of the diode |
Continuity |
If continuity exist ≤ 200Ω, built in buzzer will sound |
Battery |
9V x 1; 1.5V x 2, AA Size |
Size / Weight |
H165 x W112 x D49mm / Approx. 550g |
Standard Accessories |
Test Leads, Batteries, Manual, Carrying Case |
===================
Untuk Info dan Pemesanan Hubungi :
DARMATEK
Contact: Subarkah
Telpon : 021-71031268
H P : 081283804273/085774067221
Email : subarkah18@yahoo.co.id
Gmail : darmatek1@gmail.com
Pin BB : D2A771BD
Y M : cs_darmatek
Link :
http://darmatek.indonetwork.co.id
http://darmatek01.blogspot.com
http://tokomoisturemeter.blogspot.com
http://sirineindo.blogspot.com
Web :
http://www.darmatek.net
Tidak ada komentar:
Posting Komentar