Jual APPA 106 Thoughest Digital Multimeter
Features:
OVERLOAD PROTECTION
High energy fuses, PTCs, and fusible resistors protect APPA 100 Series multimeters, and its user, form overloads.
OPTICAL RS-232 INTERFACE
All new APPA 100 Series has RS-232 optical interface to connect to PC for data acquistion. APPA 107N and APPA 109N can be self-calibrated in connection with calibrator, also have self-data logging function without connecting to a computer.
DAY & NIGHT
All new APPA 100 Series has LED backlit display that turns ON/OFF at the touch of a button, also automatically goes off to save battery life.
EXTRA PROTECTION
Every APPA 100 Series meter is supplied with a protective holster that includes a built-in tilt stand, a nail hook, and convenient test lead storage. This holster provides an extra degree of protection and convenience for your meter.
NO-OPTION FULL ACCESSORIES
Ergonomicly designed test leads with comfort-grip, safety-shrouded, full sleeve right-angle plug and hard alloy tips for long life. Slip-on insulated alligator clips are standard. Also supplied with temperature adaptor and bead sensor.
BATTERY EASY TO REPLACE
Unscrew only two screws to remove battery door for battery replacement, designed for user's convenience without opening the bottom case.
Specifications APPA 106 :
Voltage AC
|
Range
|
400.0mV~750V
|
Basic Accuracy
|
± (1.0%+5d)
|
|
Input Impedance
|
10M?//100pF
|
|
Frequency
Response
|
40Hz~1kHz
|
|
Overload
Protection
|
1000V DC or
750V rms
|
|
Voltage DC
|
Range
|
400.0mV~1000V
|
Basic Accuracy
|
± (0.1%+1d)
|
|
Input Impedance
|
10M?
|
|
Overload
Protection
|
1000V DC or
750V rms
|
|
Current AC
|
Range
|
40.00mA~10A
|
Basic Accuracy
|
± (1.3%+5d)
|
|
Conversion Type
|
True RMS
reading on AC mode
|
|
Frequency
Response
|
40Hz~1kHz
|
|
Input
Protection
|
Equipped with
High Energy Fuse.
1A, 600V, IR
10KV fuse for mA input
15A, 600V, IR
100KV fuse for A input
|
|
Current DC
|
Range
|
40.00mA~10A
|
Basic Accuracy
|
± (0.4%+2d)
|
|
Input
Protection
|
Equipped with
High Energy Fuse.
1A, 600V, IR
10KV fuse for mA input
15A, 600V, IR
100KV fuse for A input
|
|
Resistance
|
Range
|
400.0?~40.00M?
|
Basic Accuracy
|
± (0.4%+2d)
|
|
Overload
Protection
|
600V rms
|
|
Continuity
Beeper
|
<50?, 2k Hz
tone buzzer
|
|
Diode Test
|
Open circuit
voltage
|
3V
|
Capacitance
|
Range
|
4.000nF~10mF
|
Basic Accuracy
|
± (2.0%+5d)
|
|
Overload
Protection
|
600V rms
|
|
Frequency
Counter
|
Range
|
4kHz~400MHz
|
Basic Accuracy
|
± (0.01%+1d)
|
|
Overload
Protection
|
600V rms
|
|
RPM
|
Range
|
40kRPM~400kRPM
|
Basic Accuracy
|
± (0.01%+10d)
|
|
Overload
Protection
|
600V rms
|
|
Duty Factor
|
Range
|
20%~80%
|
Basic Accuracy
|
±1%
|
|
Temperature
|
Range
|
-20°?~80°?
|
Basic Accuracy
|
±(2%+2?) at
351?~500?
|
|
Overload
Protection
|
600V rms
|
General
Specification
|
|
Sampling Rate
|
1.5times/sec
|
Overload
Indication
|
"OL",
"-OL"
|
Low Battery
Indication
|
|
Auto Power Off
|
Approx. 10
minutes
|
Operating
Temperature
|
0°~ 50°,
<80% RH
|
Storage
Temperature
|
-20°~ 60°
|
Temperature
Coefficient
|
0.15(Spec.
Acc)/?, <18? or >28?
|
Safety
|
IEC61010 and
designed to meet UL61010 specifications
|
Power
Requirement
|
Single
9V battery (NEDA 1604 or IEC 6F22)
|
Battery Life
|
300 hours
|
Size
|
76mm(W) x
158mm(L) x 38mm(H), without holster
82mm(W) x
164mm(L) x 44mm(H), with holster
|
Weight
|
400 grams (with
holster)
|
Included with
Instrument
|
Test Leads, Protective holster, ZnC battery(installed) and manual
|